670 research outputs found

    Magnetic resonance imaging: a tool for pork pie development

    Get PDF
    The traditional British pork pie consists of roughly chopped pork cooked in a hot water pastry crust. Due to shrinkage of the meat during cooking, the gap formed around the meat is usually sealed using a gelatin based jelly to exclude air and thus help to preserve the pie. The properties of the jelly are such that it will ingress into the pastry crust causing undesirable softening. The jelly is traditionally produced by simmering pig trotters with seasoning for several hours. In this work we demonstrate the potential of magnetic resonance imaging (MRI) as a tool for investigating the conditions required for producing jellies with different properties and present two examples of this use. Firstly we demonstrate that MRI can determine the ability of water to diffuse through the jelly which is critical in minimizing the amount of moisture moving from the jelly to the crust. Secondly, the impact of jelly temperature on the penetration length into the crust is investigated. These examples highlight the power of MRI as a tool for food assessment

    Cost effective power amplifiers for pulsed NMR sensors

    Get PDF
    Sensors that measure magnetic resonance relaxation times are increasingly finding applications in areas such as food and drink authenticity and waste water treatment control. Modern permanent magnets are used to provide the static magnetic field in many commercial instruments and advances in electronics, such as field programmable gate arrays, have provided lower cost console electronics for generating and detecting the pulse sequence. One area that still remains prohibitively expensive for many sensor applications of pulsed NMR is the requirement for a high frequency power amplifier. With many permanent magnet sensors providing a magnetic field in the 0.25T to 0.5T range, a power amplifier that operates in the 10MHz to 20MHz rage is required. In this work we demonstrate that some low cost commercial amplifiers can be used, with minor modification, to operate as pulsed NMR power amplifiers. We demonstrate two amplifier systems, one medium power that can be constructed for less than Euro 100 and a second much high power system that produces comparable results to commercial pulse amplifiers that are an order of magnitude more expensive. Data is presented using both the commercial NMR MOUSE and a permanent magnet system used for monitoring the clog state of constructed wetlands

    Influence of viscoelasticity and interfacial slip on acoustic wave sensors

    Get PDF
    Acoustic wave devices with shear horizontal displacements, such as quartz crystal microbalances (QCM) and shear horizontally polarised surface acoustic wave (SH-SAW) devices provide sensitive probes of changes at solid-solid and solid- liquid interfaces. Increasingly the surfaces of acoustic wave devices are being chemically or physically modified to alter surface adhesion or coated with one or more layers to amplify their response to any change of mass or material properties. In this work, we describe a model that provides a unified view of the modification in the shear motion in acoustic wave systems by multiple finite thickness loadings of viscoelastic fluids. This model encompasses QCM and other classes of acoustic wave devices based on a shear motion of the substrate surface and is also valid whether the coating film has a liquid or solid character. As a specific example, the transition of a coating from liquid to solid is modelled using a single relaxation time Maxwell model. The correspondence between parameters from this physical model and parameters from alternative acoustic impedance models is given explicitly. The characteristic changes in QCM frequency and attenuation as a function of thickness are illustrated for a single layer device as the coating is varied from liquid-like to that of an amorphous solid. Results for a double layer structure are given explicitly and the extension of the physical model to multiple layers is described

    Evaporation of microdroplets of azeotropic liquids

    Get PDF
    This work reports data showing the evolution of contact angle with time for mixtures of water and 1-propanol at room temperature on poly(methyl methacrylate) (PMMA). The composition range investigated spans the azeotropic composition, thus encompassing systems containing excess water and excess 1-propanol. A discontinuity in the contact angle behavior is observed and it is suggested that this enables the identification of the azeotropic composition as 0.39 mole fraction of 1-propanol. This suggestion is supported by boiling point measurements made at around 20 mmHg. The discontinuity is associated with the presence of an instability, which causes a distortion around the droplet perimeter. It is suggested that the distortion is caused by competing effects of local surface tension maxima and minima

    Resonant conditions for Love wave guiding layer thickness

    Get PDF
    In this work we report a systematic investigation of polymer overlayer thickness in a Love wave device working at a fundamental frequency of 110MHz and at the 330MHz harmonic. At both frequencies we observe the initial reduction in insertion loss associated with a Love wave device. Significantly, we also observe a series of resonant conditions as the layer thickness is further increased. The separation of these resonances is attributed to an increase in thickness of half of the acoustic wavelength in the polymer

    Pulse mode operation of Love wave devices for biosensing applications

    Get PDF
    In this work we present a novel pulse mode Love wave biosensor that monitors both changes in amplitude and phase. A series of concentrations of 3350 molecular weight poly(ethylene glycol) (PEG) solutions are used as a calibration sequence for the pulse mode system using a network analyzer and high frequency oscilloscope. The operation of the pulse mode system is then compared to the continuous wave network analyzer by showing a sequence of deposition and removal of a model mass layer of palmitoyl-oleoyl-sn-glycerophosphocholine (POPC) vesicles. This experimental apparatus has the potential for making many hundreds of measurements a minute and so allowing the dynamics of fast interactions to be observed

    A Low Cost Magnetic Resonance Relaxometry Sensor

    Get PDF
    Magnetic resonance relaxometry, conducted by measuring relaxation parameters at different field strengths, has become an increasingly popular technique in recent years. This technique, known as field cycling, often uses expensive and large electromagnets. In this work we present a small, portable field cycling sensor. Fast field cycling is a technique that uses a varying magnetic field applied to a sample, polarising it at a high field, allowing it time to develop at a lower field and then collecting the data at the same initial high field. This causes changes in T1 and can reveal interesting proper ties of the samples not seen by traditional methods. A prototype portable magnetic resonance sensor that undertakes relaxometry measurements using fast field cycling has been developed using a combination of permanent magnets which has been used to conduct preliminary studies on a water sample. We demonstrate the effectiveness of this sensor by conducting measurements of T1 at different field strengths

    Flexible conformable hydrophobized surfaces for turbulent flow drag reduction

    Get PDF
    In recent years extensive work has been focused onto using superhydrophobic surfaces for drag reduction applications. Superhydrophobic surfaces retain a gas layer, called a plastron, when submerged underwater in the Cassie-Baxter state with water in contact with the tops of surface roughness features. In this state the plastron allows slip to occur across the surface which results in a drag reduction. In this work we report flexible and relatively large area superhydrophobic surfaces produced using two different methods: Large roughness features were created by electrodeposition on copper meshes; Small roughness features were created by embedding carbon nanoparticles (soot) into Polydimethylsiloxane (PDMS). Both samples were made into cylinders with a diameter under 12 mm. To characterize the samples, scanning electron microscope (SEM) images and confocal microscope images were taken. The confocal microscope images were taken with each sample submerged in water to show the extent of the plastron. The hydrophobized electrodeposited copper mesh cylinders showed drag reductions of up to 32% when comparing the superhydrophobic state with a wetted out state. The soot covered cylinders achieved a 30% drag reduction when comparing the superhydrophobic state to a plain cylinder. These results were obtained for turbulent flows with Reynolds numbers 10,000 to 32,500
    • …
    corecore